INSTALLATION

VERTICAL TERMINATIONS

RIGID PIPE 4" X 6-5/8

"

The minimum components required for a basic vertical
termination are:

1 Vertical

Termination

Cap

1 45

o

Elbow

1 Rigid Pipe Adaptor (510-994)
1 Ceiling

Firestop

1 Flashing
1 Storm Collar
1 Length of pipe to suit wall thickness
(see

chart)

When using Rigid Vent other than

Simpson Dura-Vent, 3 screws must be

used to secure rigid pipe to adaptor.

This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction
with Duravent Direct-Vent, Selkirk Direct-Temp, Ameri Vent Direct Venting, ICC Excel Direct
and Security Secure Vent systems. Use of these systems with the Rigid Pipe adaptor is
deemed acceptable and does not affect the Intertek WHI listing of components.

WARNING:

Do not combine venting components from different venting systems.

However use of the the AstroCap

TM

and FPI Riser is acceptable with all systems.

The FPI AstroCap

TM

and FPI Riser Vent terminal are certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent

®

Direct Vent,

American Metal Products Ameri Vent Direct Vent, Security Secure Vent

®

, ICC Excel, Selkirk Direct-Temp. AstroCap

TM

is a proprietary trademark of FPI

Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.

Roof Pitch Minimum Vent Height

Feet Meters

fl at to 7/12

2

0.61

over 7/12 to 8/12

2

0.61

over 8/12 to 9/12

2

0.61

over 9/12 to 10/12

2.5

0.76

over 10/12 to 11/12

3.25

0.99

over 11/12 to 12/12

4

1.22

over 12/12 to 14/12

5

1.52

over 14/12 to 16/12

6

1.83

over 16/12 to 18/12

7

2.13

over 18/12 to 20/12

7.5

2.29

over 20/12 to 21/12

8

2.44

Galvanized pipe is desirable above the roofl ine due to its higher corrosion

resistance. Continue to add pipe sections through the fl ashing until the
height of the vent cap meets the minimum height requirements specifi ed in
Dia. 4 or local codes. Note that for steep roof pitches, the vertical height
must be increased. A poor draft, or down drafting can result from high
wind conditions near big trees or adjoining roof lines, in these cases,
increasing the vent height may solve the problem.

Vertical Terminal

Storm Collar

Flashing

Ceiling Firestop

Pipe

Length

Rigid Pipe Adapter

45 Elbow

o