Installation, Rigid/flex pipe venting systems, Horizontal or vertical terminations – Regency Horizon HZ42STE Medium Gas Fireplace User Manual
Page 21
Regency Horizon™ HZ42STE Gas Fireplace
21
INSTALLATION
Pipe Length
Pipe
Length
90 Elbow
o
Horizontal
Termination Cap
Wall Thimble
Vinyl Siding
Standoff (Optional)
Rigid Pipe Adapter
45 Elbow
o
RIGID/FLEX PIPE VENTING SYSTEMS
Horizontal or Vertical Terminations
The minimum components required for a basic
horizontal termination are:
1 Simpson
Duravent
Adaptor
1 Horizontal
Termination
Cap
1 45
o
Elbow
1 Rigid
Pipe
Adaptor
1 Wall
Thimble
1 Length of pipe to suit wall thickness
(see
chart)
Wall thickness is measured from the back standoffs
to the inside mounting surface of termination cap. For
siding other than vinyl furring strips may be used,
instead of the vinyl siding standoff, to create a level
surface to mount the vent terminal. The Terminal
must not be recessed into siding. Measure the wall
thickness including furring strips.
If a Vinyl Siding Standoff is required (it must be used
with vinyl siding), measure to outside surface of wall
without siding and add 2 inches.
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
This product has been evaluated by Intertek
for using a Rigid Pipe Adaptor in conjunction
with Duravent Direct-Vent , Selkirk Direct-Temp,
Ameri Vent Direct, ICC Excel, MetaFab venting
and Security Secure Vent systems. Use of
these systems with the Rigid Pipe adaptor is
deemed acceptable and does not affect the
Intertek WHI listing of components.
WARNING:
Do not combine venting components from
different venting systems.
However use of the the AstroCap
TM
and FPI
Riser is acceptable with all systems.
The FPI AstroCap
TM
and FPI Riser Vent terminal are certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent
®
Direct Vent,
American Metal Products Ameri Vent Direct Vent, ICC Excel, MetaFab, Security Secure Vent
®
, Selkirk Direct-Temp. AstroCap
TM
is a proprietary trademark
of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
Flat Wall Installation
Wall Thickness
(inches)
Vent Length Required
(inches)
4" - 5-1/2"
6"
7" - 8-1/2"
9"
10" - 11-1/2"
12"
9" - 14-1/2'
11" - 14-5/8" Adj. Pipe
15" - 23-1/2"
17" - 24" Adj. Pipe