Installation, Wiring diagram – Regency Horizon HZ42STE Medium Gas Fireplace User Manual
Page 33
Regency Horizon™ HZ42STE Gas Fireplace
33
INSTALLATION
WIRING DIAGRAM
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
0.886.001
Proflame Valve
Standard Main On/Off Switch
or Optional Wall Switch
SureFire™ Switch
Note: 4 AA batteries must be installed to operate
the burner switch.
Do not use a 9 volt battery.
IMPORTANT:
If the optional remote control is used, the AA batteries normally installed into the battery holder must be removed. The AA batteries in the
receiver now operate the unit. Having AA batteries in both the battery holder and receiver will damage the gas valve.
Electrical Connection Alternative Scheme "B",
Power at Switch
Wall Junction Box
*Speed Control
Switch with lead wires
Wire Nuts
14 AWG wire
*Wire Clamp
120 Volts
60 Hz
Copper Ground
White (Neutral)
Black (Hot)
Wire
Black
White
Ground
*Receptacle Box
inside stove
~
*Receptacle
(dedicated use
by unit fan only)
* = supplied with fan kit
Other parts are to be supplied
by electrician or installer
Power
Switch
Receptacle
in Unit
To Fan (see above)
Ground
L1
N
Black
Red
Ground
Break Tab
Copper terminals
Black
Do Not Break Tab
on Neutral (silver terminals)
Fan
Speed
Control
AC Adaptor (see AC Adaptor in