beautypg.com

Installation, Locating your gas fireplace, Installation checklist – Regency Bellavista B41XTCE Large Gas Fireplace User Manual

Page 9

background image

Regency Bellavista™ B41XTCE Gas Fireplace

9

INSTALLATION

This includes:

1) Clocking the appliance to ensure the correct

fi ring rate (rate noted on label), after burning
appliance for 15 minutes.

2) If required, adjusting the primary air to ensure

that the fl ame does not carbon. First allow
the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.

LOCATING YOUR

GAS FIREPLACE

A) Flat on Wall
B) Flat on Wall Corner
C) Recessed into Wall/Alcove
D) Corner

Diagram 1

1) When selecting a location for your fi replace,

ensure that the clearances are met.

2) The appliance must be installed on a fl at,

solid, continuous surface For example a
wood, metal or concrete fl oor or in a raised (on
the wall) application. The appliance must be
installed on a metal or wood panel extending
the full width and depth of the appliance.

3) The B41XTCE Gas Fireplace can be installed

in a recessed position or framed out into the
room as in A, B, C and D. See Diagram 1.

INSTALLATION

CHECKLIST

1) Locate appliance

a) Room location (Refer to "Locating Your

Gas fi replace" section)

b) Clearances to Combustibles (Refer to

"Clearances" section)

c) Mantle Clearances (Refer to "Combustible

Mantel Clearances" section)

d) Framing & Finishing Requirements (Refer

to "Framing & Finishing" section)

e) Venting Requirements (Refer to "Venting"

section)

2) Assemble Top Standoffs and Top Facing

Support and Side Nailing Strips (Refer to
"Unit Assembly Prior to Installation" Section).
Note: Must be done before installing unit into
place.

3) Install vent (Refer to "Venting" sections).

4) Make gas connections. Test the pilot. Must be

as per diagram (Refer to "Pilot Adjustment"
section).

5) Make electrical connections to receptacle

supplied with unit (recommended).

6) Install standard and optional features. Refer

to the following sections:


a. Install 4AA batteries into battery pack

b. Inner Panels or Brick Panels (Required)

c. Log Set Installation

d. Standard Flush Door

e. Remote Control

f. Wall Switch

g.

Wall

Thermostat

h. Fan Installation (Optional)

i. Light Installation (Optional)


7) Final check.

4) This appliance is Listed for bedroom

installations using the standard Remote
(millivolt thermostat system). Some areas
may have further requirements, check local
codes before installation.

5) The B41XTCE Gas Fireplace are approved

for alcove installations, see "Clearances"
section for details.

6) We recommend that you plan your installation

on paper using exact measurements for
clearances and floor protection before
actually installing this appliance. Have an
authorized inspector, dealer, or installer
review your plans before installation.

Note: For vent terminations refer to

"Exterior Vent Termination Locations"
section.