beautypg.com

Maintenance, Valve replacement, Installing valve – Regency Bellavista B41XTCE Large Gas Fireplace User Manual

Page 62

background image

62

Regency Bellavista™ B41XTCE Gas Fireplace

MAINTENANCE

VALVE REPLACEMENT

11) Remove the 14 screws securing the

valve tray assembly in place (Diagram
7) and then lift the entire assembly out
Also remove the valve gasket.

1) Shut off the gas and electrical supply.

2) Remove the louvers

3) Open the fl ush door and remove the door.

4) Remove the logs.

5) Remove the burner/grate assembly by
removing the 2 screws.

Diagram 1: Remove the left and right screws.

Diagram 2: Slide burner assembly to the right

and then remove.

7) Remove the 2 screws securing the rear log

tray and lift out. Diagram 3

8) Remove the 2 screws securing the burner

tray - lift burner tray up and out. Diagram
4a and 4b.

Diagram 5

Diagram 4a

Diagram 4b

Diagram 3

Diagram 7

INSTALLING VALVE

1) Place new valve tray and gasket into position.

2) Reinstall the 14 hold down screws.

3) Connect the EV1, EV2 and ground wires to

the appropriate connections on the valve.

4) Reinstall the rear log tray.

5) Install burner/grate assembly

6) Hook up the gas line and check for gas leaks

with a soap and water solution or a gas leak
detector. (Do not use open fl ame for leak
testing.)

7) Fire up the unit temporarily

8) Check the manifold pressure.

9) Reinstall the logs and brick panels as

needed.

10) Reinstall the door and replace the louvers.

11) Fire up the unit again and check for proper

fl ame appearance and glow on logs.

6) Slide the burner assembly to the right to

release it from the orifi ce, then lift it out.

9) Disconnect the inlet gas line. See Diagram

5.

10) Disconnect the EV1, EV2, and ground wires

from the valve - as shown below.

EV1

EV2

Ground