beautypg.com

Installation, Optional fan installation – Regency Bellavista B41XTCE Large Gas Fireplace User Manual

Page 43

background image

Regency Bellavista™ B41XTCE Gas Fireplace

43

INSTALLATION

OPTIONAL FAN INSTALLATION

Important: 120 Volt AC power is needed for the fan switch and blower.
The receptacle box will be installed on the left hand side of the unit
and must be wired by a qualifi ed electrician prior to fan
assembly being installed. The neutral(wider) slot of the polarized
receptacle should be at the top.

Ground terminal must not be removed.
Unit must be grounded at all times.

1) Turn the power off, unplug accent lights if installed.

2) Remove bottom access panel or louver, if necessary. Remove the

standard fl ush door.

3) Remove fan assembly from box, locate green ground wire and pull

out of fan assembly - taking care not to damage or cut wire casing.

4) Connect the Black wire to the left side terminal of the fan motor.

Slide the black wire and the green ground wire into grommet and
push grommet into the fan assembly housing.

5) Connect the Red wire onto the right side terminal of the fan motor,

Connect the red wire into the grommet and push grommet into the
fan assembly housing.

BLACK

RED

6) Position the fan base with the motor end towards the rear of the

fi rebox and then slide the fan in towards the rear of the unit. Turn
the fan housing slightly to the left and make the fan assembly paral-
lel to the rear wall.

7) Lift the fan housing upwards and slip it over the two mounting

studs. (use of dish soap will help the rubber grommets slide down
over the pins)

NOTE: If optional accent lights are installed,take care when sliding the
fan into position. Fan must be maneuvered around the right
side of the light.

8) Connect and secure fan ground cable to ground lug.