beautypg.com

Installation, Proflame system wiring diagram – Regency Bellavista B41XTCE Large Gas Fireplace User Manual

Page 53

background image

Regency Bellavista™ B41XTCE Gas Fireplace

53

INSTALLATION

Proflame System
Configuration
886 GTMF
Wire Diagram

PROFLAME SYSTEM WIRING DIAGRAM

CONFIGURATION: 886 ON/OFF STAND ALONE

PROFLAME SYSTEM WIRING DIAGRAM

CONFIGURATION: 886 GTMF

0.886.001

Proflame Valve

Standard Main On/Off Switch
or Optional Wall Switch

GT, GTM, GTMF

Option

GTMF Option

GTM Option

PROFLAME REMOTE SERIES

946-690

GT Remote System

946-691*

GTM Remote System

946-692*

GTMF Remote

* Must also order a 946-693-NG or 946-694 modulator
if using the noted remote controls.

SureFire™ Switch

SureFire™ Switch

Note: 4 AA batteries must be installed to
operate the burner switch. Do not use a 9 volt
battery.

IMPORTANT:

If the optional remote control is used, the AA batteries normally installed into the battery holder must be removed. The AA

batteries in the receiver now operate the unit. Having AA batteries in both the battery holder and receiver will damage the gas valve.