INSTALLATION

VERTICAL TERMINATIONS

THREE (3) 90

O

ELBOWS (RIGID PIPE 5" X 8")

One 90

o

elbow = Two 45

o

elbows.

Option

V

V + V1

H + H1

W i t h t h e s e o p t i o n s ,
maximum total pipe length
is 30 feet with minimum
of 6 feet total vertical
and maximum 8 feet total
horizontal.

Please note minimum 1
foot between 90

o

elbows is required.

A)

0' Min.

2' Min.

2' Max.

B)

1' Min.

3' Min.

2' Max.

C)

2' Min.

4' Min.

3' Max.

D)

3' Min.

6' Min.

4' Max.

E)

4' Min.

7' Min.

5' Max.

F)

5' Min.

8' Min.

6' Max.

G)

6' Min.

9' Min.

7' Max.

H) 7'

Min

10' Min.

8' Max.

No Vent Restrictor Installed

Lengths do not include elbow indicated.

Must use rigid pipe adaptor #770-994

V

H1

H