beautypg.com

Installation, Horizontal terminations – Regency Bellavista B41XTCE Large Gas Fireplace User Manual

Page 24

background image

24

Regency Bellavista™ B41XTCE Gas Fireplace

INSTALLATION

HORIZONTAL TERMINATIONS

FLEX VENT 5" X 8"

These venting systems, in combination with the B41XTCE Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by
Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent
Termination Locations" section.

Regency

®

Direct Vent (Flex) System 4 foot Termination Kit (Part# 946-615) or 10 foot Termination Kit (Part# 946-616) includes all the parts

needed to install the B41XTCE with a either a top or rear vent.

Notes:
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from Regency may be used for Flex installations.
3) Regency

®

Direct Vent System (Flex) is only approved for horizontal terminations.

NOTE: If longer runs are required the FPI Direct Vent system (Flex) #946-616 includes
all parts needed to install the B41XTCE with a maximum 10' run.

FPI Kit #

Length Contains:

#946-615

4 Feet

1) 8”

fl exible liner (Kit length)

2) 5”

fl exible liner (Kit length)

3) spring

spacers

4) thimble
5) AstroCap XL termination cap
6) screws
7) tube of Mill Pac
8) plated

screws

9) S.S. screws #8 x 1-1/2” drill point
10) vinyl siding standoff

#946-618

6 Feet

#946-616

10 Feet

IMPORTANT

Must use Rear Venting Defl ector

packaged with unit in rear vent

horizontal termination applications.