INSTALLATION

GAS PIPE

PRESSURE TESTING

The appliance must be isolated from the gas
supply piping system by closing its individual
manual shut-off valve during any pressure
testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig.
(3.45 kPa). Disconnect piping from valve at
pressures over 1/2 psig.

The manifold pressure is controlled by a regulator
built into the gas control, and should be checked
at the pressure test point.

Note: To properly check gas pressure, both

inlet and manifold pressures should
be checked using the valve pressure
ports on the valve.

1) Make sure the valve is in the "OFF"

position.

2) Loosen the "IN" and/or "OUT" pressure

tap(s), turning counterclockwise with a 1/8"
wide fl at screwdriver.

3) Attach manometer to "IN" and/or "OUT"

pressure tap(s) using a 5/16" ID hose.

4) Light the pilot and turn the valve to "ON"

position.

5) The pressure check should be carried out

with the unit burning and the setting should
be within the limits specifi ed on the safety
label.

6) When fi nished reading manometer, turn

off the gas valve, disconnect the hose and
tighten the screw (clockwise) with a 1/8" fl at
screwdriver. Note: Screw should be snug,
but do not over tighten.

HIGH ELEVATION

This unit is approved in Canada for altitude to
4500 ft. (CAN/CGA-2.17-M91). For Natural Gas
installations above 4500 ft. follow current CAN/
CGA-B149.1.

B41XTCE -NG System Data

For 0 to 4500 feet altitude
Burner Inlet Orifi ce Sizes:

#30

Max. Input Rating 42,500 Btu/h
Min. Input Rating

30,000 Btu/h

Supply Pressure min.5.0"

w.c.

Manifold Pressure
(High)

3.5"+/- 0.2" w.c.

Manifold Pressure
(Low)

1.6"+/- 0.2" w.c.

B41XTCE - LP System Data

For 0 to 4500 feet altitude
Burner Inlet Orifi ce Sizes:

#49

Max. Input Rating 3 7 , 5 0 0 B t u / h
Min. Input Rating

2 9 , 5 0 0 B t u / h


Supply Pressure min.11.0"

w.c.

Manifold Pressure
(High)
10"+/-

0.2"w.c.

Manifold Pressure
(Low)
6.4"+/-

0.2"w.c.

PILOT ADJUSTMENT

Note: If

you

have an incorrect fl ame pattern,

contact your Regency

®

dealer for

further instructions.

Incorrect fl ame pattern will have small,
probably yellow fl ames, not coming into
proper contact with the rear burner or fl ame
sensor.

Burner

Flame Sensor

Pilot

Ignitor

Periodically check the pilot fl ames. Correct
fl ame pattern has two strong blue fl ames:
1 fl owing around the fl ame sensor and 1
fl owing across the burner (it does not have
to be touching the burner).

886 S.I.T. VALVE DESCRIPTION

1) Manual high/low adjustment
2) Pilot adjustment
3) Outlet Pressure Tap
4) Inlet Pressure Tap
5) Pilot Outlet
6) Main Gas Outlet
7) Main Gas Inlet

1

3

2

4

5

6

7