beautypg.com

Installation, Horizontal terminations – Regency Bellavista B41XTCE Large Gas Fireplace User Manual

Page 29

background image

Regency Bellavista™ B41XTCE Gas Fireplace

29

INSTALLATION

V1

H1

H

V

H

H1

V

HORIZONTAL TERMINATIONS

TWO (2) 90

O

ELBOWS (RIGID PIPE 5" X 8")

HORIZONTAL TERMINATIONS

THREE (3) 90

O

ELBOWS (RIGID PIPE 5" X 8")

One 90

o

elbow = Two 45

o

elbows.

Option

V

H + H1

With these options,
maximum total pipe
length is 30 feet with
minimum of 6 feet total
vertical and maximum 8
feet total horizontal.
Please note minimum
1 foot between 90

o

elbows is required.

A)

0' Min.

2' Max.

B)

1' Min.

3' Max.

C)

2' Min.

4' Max.

D)

3' Min.

5' Max.

E)

4' Min.

6' Max.

F)

5' Min.

7' Max.

G)

6' Min.

8' Max.

No Vent Restrictor Installed

Lengths do not include elbow indicated.

Must use rigid pipe adaptor #770-994.

One 90

o

elbow = Two 45

o

elbows.

Option

V

H

V + V1

H + H1

W i t h t h e s e
options, maximum
total pipe length
is 30 feet with
minimum of 6 feet
total vertical and
maximum 8 feet
total horizontal.
Please note mini-
mum 1 foot be-
tween 90

o

elbows is
required.

A)

0' Min.

1' Max.

1' Min.

2' Max.

B)

1' Min.

2' Max.

3' Min.

3' Max.

C)

2' Min.

2' Max.

5' Min.

4' Max.

D)

3' Min.

2' Max.

7' Min.

5' Max.

E)

4' Min.

3' Max.

9' Min.

6' Max.

F)

5' Min.

4' Max.

10' Min.

7' Max.

G)

6' Min.

5' Max.

11' Min.

8' Max.

H)

7' Min.

6" Max.

12' Min.

9' Max.

No Vent Restrictor Installed

Lengths do not include elbow indicated.

Must use rigid pipe adaptor #770-994.