beautypg.com

Ab c, Installation, Mantel clearances – Regency Bellavista B41XTCE Large Gas Fireplace User Manual

Page 11

background image

Regency Bellavista™ B41XTCE Gas Fireplace

11

INSTALLATION

MANTEL CLEARANCES

Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour.

Due to the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are
shown in the diagram on the right.

Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible

board.

Mantel Clearances
B41XT

A

B

C

D

From Top of
Fireplace Opening

32-11/16"

(830mm)

25-13/16"

(656mm)

22-1/16"

(560mm)

17-9/16"

(446mm)

Combustible

Mantel Clearances

2

0

12

6

4

8

10

0

Top of

Fireplace

Opening

12”

1"

7”

A

B

C

Non-combustible

Header

(steel stud)

on edge

14

To Floor

12

24

Inches

D

6”

Non-combustible

Standoff