Regency Bellavista™ B41XTCE Gas Fireplace

23

INSTALLATION

The diagrams show all allowable combinations of vent runs with 5" x 8" venting using the Regency direct vent system or rigid vent system.
A vent guard should be used whenever the termination is lower than the specifi ed minimum or as per local codes.

For horizontal terminations the Regency Direct Vent Flex System may be used for installations upto a maximum

continuous vent length of 10ft (3.0m).

Note: Must use optional rigid pipe adaptor (Part # 770-994) when using Rigid Pipe vent systems.

• Maintain clearance to combustibles.
• Horizontal vent must be supported every 3 feet.
• Firestops are required at each fl oor level and whenever passing through a wall.

2

0

12

6

4

8

10

2

0

6

4

8

V

ertical

Height

(Feet)

Rigid

or

Flex

47-1/2"

(1.2m)

Horizontal (Feet)

Max. 36”(0.9m)

2

0

6

4

8

2

0

6

4

8

V

ertical

Height

(Feet)

28

-

1/2"(0.7m)

Horizontal (Feet)

Max. 36"(0.9m)

Vent Restrictor - Set 1

Factory Setting - No Restrictor Required

VENTING ARRANGEMENTS FOR HORIZONTAL TERMINATIONS

FLEX VENT OR RIGID PIPE 5" X 8"

REAR VENTING DEFLECTOR INSTALLATION

FOR REAR VENTED HORIZONTAL TERMINATIONS

Rear Venting Defl ector

The Rear Vent Defl ector comes with the unit. When the unit is shipped
the defl ector is slightly tucked underneath the top nailing strips located
at the top of the fi rebox.

NOTE: The Rear Venting Defl ector must be installed before the unit is
put in place.

IMPORTANT

Must use Rear Venting Defl ector packaged with unit in

rear vent horizontal termination applications.

Rear Venting

Deflector

1) Secure the rear venting

defl ector to the wall thimble
using 2 screws as shown.
Ensure to use the same screw
holes as the wall thimble.