beautypg.com

Aeris system troubleshooting – STEMCO Aeris Inflation System Troubleshooting User Manual

Page 16

background image

Aeris System Troubleshooting

Sept 2013

Page 16 of 18

Continued from Page 15

Condition: Tires are not within a few PSI of each other after light goes off after power up.

Possible causes: Kinked or damaged ¼ inch air line. Incorrect valve core in hose or damage hose check valve.

(From Previous Page)

Low or no air flow

detected with hose

removed from tire

valve stem.

¼” air line is restricted

between RAU & control

box. Check line in axle

tube and work backwards.

Repair as needed.

Yes

No

Remove RAU from hub

and disconnect the ¼” air

line. Is high volume of air

flow detected?

RAU is damaged,

replace RAU hose

Verify repairs

by completing

Power on Test

Verify repairs

by completing

Power on Test