Aeris System Troubleshooting

Sept 2013

Page 13 of 18

Condition: Driver Warning Lamp comes on but does not flash three times and does not go off

Possible cause: Driver Warning Lamp has constant power

Before starting this section

Verify the wires are attached to control unit circuit board as shown in figure 3 on page 18
(Note: Incorrect attachment of wires may cause circuit board damage)

Connect test light to the

circuit board yellow & white

wires. Is test light on?

Yes

No

If test light illuminates and
did not flash a bad circuit
board is indicated

(See note 1 on Page 18
before replacing control box)

Remove yellow wire from

circuit board. Did Driver

Warning Lamp go off?

Yes

No

Connect test light to top

terminal on circuit board.

Yellow Driver

Warning Lamp wire

is shorted to power.

Find short & repair

Verify repairs

by completing

Power on Test

Driver Warning Lamp is

not correctly wire at the

nose of the trailer.

Correct wiring

Verify repairs

by completing

Power on Test