Aeris System Troubleshooting

Sept 2013

Page 14 of 18

Condition: Light stays on after 3 flashes at power up (flashing or steady Driver Warning Lamp) and does

not go off

Possible causes: System has detected air flow or has no air supply (check air supply to trailer before

continuing)

Verify air supply valve on the

outside of the control box is in

the open position

(See figure 1

on page 18)

Open Valve

Recheck

pressure

in all tires

Complete

Power on Test

again

Check pressure

regulator setting

inside control box.

Is regulator set to

desired pressure?

Low tire

found?

Set to desired

level

No problem

found

No

Yes

No

Yes

Yes

No

Repair

leak in tire

Complete

Power on Test

again

Complete

Power on Test

again

Inspect all air

lines, fittings

and hoses for

leaks

Repair leak

Leak

found?

Yes

No

Complete

Power on Test

again

Complete

Power on Test

again