Aeris System Troubleshooting

Sept 2013

Page 15 of 18

Condition: Tires are not within a few PSI of each other after light goes off after power up.

Possible causes: Kinked or damaged ¼ inch air line. Incorrect valve core in hose or damage hose check valve.

Go to tire that is low and

disconnect hose from tire valve

stem. Is there a high volume of

air coming out of hose?

Low volume or no air flow is

caused by restriction in ¼” air

line or hose. Replace hose with

known good. Is there a high

volume of air coming out of

hose?

Verify air supply valve on the

outside of the control box is in

the open position and air filter

is not plugged. Is valve open

and filter clear?

(See figure 1 on

page 18)

No

Open Valve

Complete

Power on Test

again

Yes

No

Check valve stem core for

proper operation. Repair as

needed.

Complete

Power on Test

again

Yes

No

Hose was damaged,

replace hose

Complete

Power on Test

again

Yes

Continue

on page 16