beautypg.com

Aeris system troubleshooting – STEMCO Aeris Inflation System Troubleshooting User Manual

Page 11

background image

Aeris System Troubleshooting

Sept 2013

Page 11 of 18

Condition: Driver Warning Lamp does not come on at all

Possible Causes: Loose, broken or corroded connection or wires, bad bulb or bad control box circuit board

Before starting this section

Verify power and ground connections supplying the trailer
Verify control box is wired correctly (see figure 3 on page 18)

CAUTION: DO NOT SHORT CONTROL BOX WIRES TOGETHER WHILE THEY ARE CONNECTED TO THE CIRCUIT

BOARD. CONTROL UNIT DAMAGE MAY RESULT

(Note: Do not use a volt meter to conduct these tests. A test light is required)

Open control box. Is light

illuminated on circuit

board (flashing or solid)?

Yes

Yes

Yes

No

No

No

Disconnect Yellow and Brown

wires from the circuit board

and short them together. Is

Driver Warning Lamp on?

Poor lamp ground, burnt

out bulb or wiring to the

front of trailer is bad,

repair as needed

Reconnect Yellow wire then
Brown wire to circuit board.
Did circuit board light come
on and flash 3 times?

Yes

Complete Power on Test

again, circuit board is

operating properly

If circuit board light does not
flash three times a bad circuit
board is indicated

(See note 1 on Page 18 before
replacing control box)

Go to Page 12

Verify repairs

by completing

Power on Test