SECTION 7 MAINTENANCE AND SERVICING

169000

124

Revision F

7.8.9 Knife Drive Belts: A30-D

7.8.9.1

Adjusting Tension: LH Knife Drive
Timing Belt - A30-D

IMPORTANT

To prolong belt and drive life, do NOT
over-tighten belts.

CAUTION

Stop engine, and remove key from ignition
before leaving Operator’s seat for any
reason. A child or even a pet could engage
an idling machine.

a. Open LH endshield.

b. Loosen three nuts (B).

c. Loosen jam nut on adjuster bolt (C).

d. Turn adjuster bolt (C) to move pulley (D) until a

force of 5–6.5 lbf (22–30 N) deflects belt (A)
0.55 in. (14 mm) at mid-span.

e. Tighten jam nut at (C), and three nuts (B).

f. Close

endshield.

g. Readjust tension of a new belt after a short

run-in period (about 5 hours).

7.8.9.2

Removing LH Knife Drive Belts: A30-D

a. Open LH endshield.

b. Loosen nut (E) on idler sprocket.

c. Turn adjuster bolt (F) to loosen chain so that it

can be removed from large sprocket (G).

d. Loosen nuts (H), and jam nut on adjuster

bolt (J).

e. Turn adjuster bolt (J) to loosen V-belts (K) so

that belts can be slipped off pulley (D).

(continued next page)

K

D

H

J

B

C

A

D

A

E

F

G

This manual is related to the following products: