beautypg.com

Warning – MacDon A40-D Pull-Type User Manual

Page 117

background image

SECTION 7 MAINTENANCE AND SERVICING

169000

115

Revision F

7.7 HYDRAULICS

7.7.1 Hydraulics:

Self-Propelled

Refer to your self-propelled windrower
operator’s manual for hydraulic system
maintenance procedures for

self-propelled windrowers.

7.7.2 Hydraulics:

Pull-Type

The pull-type mower conditioner is hydraulically
powered using the following systems:

• A self-contained hydraulic system to operate

the header functions.

• The tractor remote system to operate the

header lift cylinders and steering.

WARNING

Do NOT use remote hydraulic system
pressures over 3000 psi (20684 kPa). Check
your tractor’s operator’s manual for remote
system pressure.

7.7.2.1 Reservoir

The mower conditioner’s self-contained
hydraulic system uses the Articulating Power
Tongue (APT) of the machine for the hydraulic
oil reservoir.

7.7.2.2 Oil

Level

Check oil level daily (before start-up) at the sight
gauge on the left side of the Articulating Power
Tongue (APT). Oil level should be at or near
FULL mark on the gauge when top surface of
APT is level, and oil is cold.

7.7.2.3

Adding Hydraulic Oil

a. Slowly unscrew filler cap (A) from filler tube.

b. Add SAE 15W40 oil until level is between ADD

and FULL marks on sight gauge.

c. Replace filler cap.

7.7.2.4

Changing Hydraulic Oil

NOTE

Change hydraulic oil every 500 hours, or
3 years.

NOTE

A drain pan with a capacity of

35 US gallons (130 liters) will

be required.

NOTE

Mower conditioner must be
disconnected from tractor. Refer to
Section 6.5 MOWER CONDITIONER/
TRACTOR UNHOOK: PULL-TYPE.

a. Remove filler cap (A) at aft end of Articulating

Power Tongue (APT).

b. Disconnect pump suction hose (B) from pump,

and drain into container.

c. Reconnect pump suction hose to pump.

d. Fill reservoir to recommended level with SAE

15W30 oil. Capacity is 33 US gallons

(126 liters).

B

A

This manual is related to the following products: