beautypg.com

Brother BES-1261BC User Manual

Page 56

background image

BES-961BC

BES-1261BC

54

Chapter 2 Embroidering Procedures

THREAD SENSOR lamp

When red light is on, thread breakage sensor is functioning. When the light is off,

the sensor is not effective. When the embroidery machine stops due to thread

breakage, the lamp flashes.

HEAD switch

When it is set to ON, needle bar on the head moves for embroidering. When it is

set to OFF, the needle bar does not move for embroidering.

MENDING lamp

This lamp lights up when the embroidery machine is in the mending mode.

A lamp on the head with an error lights up. (only when the error can be located)

MENDING switch

This switch is set to upside to drive or to suspend the machine head during

embroidering for a designated period of time.

STEP BACK/FWD switch

When it is turned to BACK, the machine steps back. When it is turned to FWD,

the machine steps forward. If you keep the switch turned for a while, the machine

will continue stepping even after you let the switch alone. When it is turned to the

opposite side, the machine stops.

During timing adjustment of the rotary hook in the test mode, the rotary hook

slightly rotates to the left/right when this switch is turned to left/right respectively.

Refer to "Adjustment of timing Between Needle and Rotary Hook" (

page 144)

for further details.

If any error occurs, it can be reset.