Bryant PACKAGED HEAT PUMP 548J User Manual

Page 34

background image

34

Table 18 – HEATING CAPACITY

7.5 TONS

548J*08

RETURN

AIR

(°F db)

CFM

(STANDARD AIR)

TEMPERATURE AIR ENTERING OUTDOOR COIL (°F db at 70% rh)

---10

0

10

17

30

40

47

50

60

55

2250

Capacity

46.9

53.5

66.3

77.2

86.2

89.4

103.3

Int. Cap.

43.1

48.7

58.1

77.2

86.2

89.4

103.3

3000

Capacity

68.5

80.2

89.8

93.1

106.7

Int. Cap.

60.0

80.2

89.8

93.1

106.7

3750

Capacity

58.9

72.5

84.6

94.5

97.6

110.6

Int. Cap.

53.7

63.5

84.6

94.5

97.6

110.6

70

2250

Capacity

25.9

34.6

43.6

50.2

62.7

73.0

81.4

84.5

98.0

Int. Cap.

23.9

31.8

40.0

45.7

55.0

73.0

81.4

84.5

98.0

3000

Capacity

27.4

36.2

45.5

52.2

65.1

75.9

85.0

88.2

102.1

Int. Cap.

25.3

33.4

41.8

47.6

57.0

75.9

85.0

88.2

102.1

3750

Capacity

31.0

40.0

49.3

56.1

69.1

80.4

89.8

93.2

106.5

Int. Cap.

28.6

36.8

45.3

51.1

60.6

80.4

89.8

93.2

106.5

80

2250

Capacity

22.5

31.5

40.7

47.3

60.1

70.3

78.2

81.2

94.3

Int. Cap.

20.8

29.0

37.3

43.1

52.6

70.3

78.2

81.2

94.3

3000

Capacity

24.1

33.3

42.7

49.5

62.5

73.1

81.6

84.7

98.6

Int. Cap.

22.3

30.6

39.2

45.2

54.8

73.1

81.6

84.7

98.6

3750

Capacity

27.8

37.1

46.6

53.5

66.7

77.5

86.4

89.7

103.4

Int. Cap.

25.7

34.1

42.8

48.8

58.4

77.5

86.4

89.7

103.4

Table 19 – HEATING CAPACITY

8.5 TONS

548J*09

RETURN

AIR

(°F db)

CFM

(STANDARD AIR)

TEMPERATURE AIR ENTERING OUTDOOR COIL (°F db at 70% rh)

---10

0

10

17

30

40

47

50

60

55

2550

Capacity

33.1

42.7

52.7

60.0

75.6

87.4

97.5

100.6

113.8

Int. Cap.

30.7

39.3

48.3

54.7

66.2

87.4

97.5

100.6

113.8

3400

Capacity

34.4

44.0

54.2

61.8

77.5

89.9

100.2

103.1

115.7

Int. Cap.

31.8

40.5

49.8

56.4

67.9

89.9

100.2

103.1

115.7

4250

Capacity

38.0

47.7

58.0

65.8

81.5

94.2

103.9

106.6

118.2

Int. Cap.

35.2

43.9

53.2

60.0

71.4

94.2

103.9

106.6

118.2

70

2550

Capacity

29.0

38.6

48.6

55.9

70.7

83.5

93.1

96.2

109.5

Int. Cap.

26.8

35.5

44.6

51.0

61.9

83.5

93.1

96.2

109.5

3400

Capacity

30.3

40.2

50.4

58.0

73.5

86.1

96.5

99.2

111.9

Int. Cap.

28.0

37.0

46.3

52.9

64.4

86.1

96.5

99.2

111.9

4250

Capacity

34.0

44.0

54.4

62.1

77.8

90.5

100.5

103.3

115.2

Int. Cap.

31.5

40.5

50.0

56.6

68.2

90.5

100.5

103.3

115.2

80

2550

Capacity

25.3

35.0

45.2

52.6

67.1

80.0

90.0

93.2

106.5

Int. Cap.

23.4

32.2

41.5

48.0

58.8

80.0

90.0

93.2

106.5

3400

Capacity

26.6

36.7

47.2

54.8

69.8

83.0

93.1

96.2

109.2

Int. Cap.

24.6

33.8

43.3

50.0

61.2

83.0

93.1

96.2

109.2

4250

Capacity

30.4

40.6

51.2

59.0

74.4

87.7

97.7

100.7

112.8

Int. Cap.

28.1

37.4

47.0

53.8

65.1

87.7

97.7

100.7

112.8

--- Indicates operation not permissible

LEGEND

Capacity --- Instantaneous Capacity (1000 Btuh) includes indoor fan motor heat @ARI static conditions

Int. Cap. --- Integrated Capacity is Instantaneous Capacity minus the effects of frost on the outdoor coil and the heat required to defrost
rh

--- Relative Humidity

db

--- Dry Bulb

548J