FEATURES AND BENEFITS

S

Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement jobs.

S

3--8.5 ton units fit on existing Bryant rooftop curbs making the utility connections the same. This saves time and money
on replacement jobs.

S

Standardized components and layout. Standardized components and controls make service and stocking parts easier.

S

Scroll compressors on all units. This makes service, stocking parts, replacement, and trouble--shooting easier.

S

Crankcase heater on all models (except 04 size) provides added protection in all applications.

S

Precession sized suction line accumulator provide high reliability by preventing liquid from entering the compressor
during low ambient conditions and reverse cycle switch over.

S

Field convertible airflow (3--8.5 tons). Being able to convert a unit from vertical airflow to horizontal makes it easy to
overcome job site complications.

S

4--way reversing valve rapidly changes the flow of refrigerant to quickly changeover from cooling to heating and heating
to cooling.

S

Easy--adjust, belt--drive motor available on all sizes. Bryant provides a factory solution for most points in the fan
performance table. There’s no need for field--supplied drives or motors.

S

3--5 ton models come standard with an Electric Drive X13, 5 speed/torque motor to provide exact performance in many
applications. Belt drive motor optional.

S

Provisions for bottom or side condensate drain.

S

Capable of thru--the--base or thru--the--curb electrical routing.

S

Dependable time/temperature defrost logic provides a defrost cycle, if needed, every 30, 60, 90 or 120 minutes and is
adjustable.

S

Single--point electrical connection.

S

Sloped, composite drain pan. Sloped, composite drain pan sheds water; and won’t rust.

S

Standardized controls and control box layout. Standardized components and controls make stocking parts and service
easier.

S

Clean, easy to use control box.

S

Standard coils are copper round tube, aluminum plate fin with optional coil coatings and copper fin design.

S

Color--coded wiring.

S

Large, laminated wiring and power wiring drawings which are affixed to unit make troubleshooting easy.

S

Single, central terminal board for test and wiring connections.

S

Fast--access, handled, panels for easy access to the blower and blower motor, control box, and compressors.

S

“No--strip” screw system guides screws into the panel and captures them tightly without stripping the screw, the panel, or
the unit.

S

Exclusive, newly--design indoor refrigerant header for easier maintenance and replacement.

S

Mechanical cooling (115_F to 25_F or 46_C to --4_C) on Electro--Mechanical (E/M) and Direct Digital Controller
(DDC) (RTU--MP controller).

S

2” (51mm) disposable filters on all units.

S

High capacity refrigerant filter--drier on each circuit.

S

High pressure switch, loss of charge switch and freeze protection adds greater unit reliability.

548J