Features and benefits – Bryant PACKAGED HEAT PUMP 548J User Manual
Page 3

3
FEATURES AND BENEFITS
S
Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement jobs.
S
3--8.5 ton units fit on existing Bryant rooftop curbs making the utility connections the same. This saves time and money
on replacement jobs.
S
Standardized components and layout. Standardized components and controls make service and stocking parts easier.
S
Scroll compressors on all units. This makes service, stocking parts, replacement, and trouble--shooting easier.
S
Crankcase heater on all models (except 04 size) provides added protection in all applications.
S
Precession sized suction line accumulator provide high reliability by preventing liquid from entering the compressor
during low ambient conditions and reverse cycle switch over.
S
Field convertible airflow (3--8.5 tons). Being able to convert a unit from vertical airflow to horizontal makes it easy to
overcome job site complications.
S
4--way reversing valve rapidly changes the flow of refrigerant to quickly changeover from cooling to heating and heating
to cooling.
S
Easy--adjust, belt--drive motor available on all sizes. Bryant provides a factory solution for most points in the fan
performance table. There’s no need for field--supplied drives or motors.
S
3--5 ton models come standard with an Electric Drive X13, 5 speed/torque motor to provide exact performance in many
applications. Belt drive motor optional.
S
Provisions for bottom or side condensate drain.
S
Capable of thru--the--base or thru--the--curb electrical routing.
S
Dependable time/temperature defrost logic provides a defrost cycle, if needed, every 30, 60, 90 or 120 minutes and is
adjustable.
S
Single--point electrical connection.
S
Sloped, composite drain pan. Sloped, composite drain pan sheds water; and won’t rust.
S
Standardized controls and control box layout. Standardized components and controls make stocking parts and service
easier.
S
Clean, easy to use control box.
S
Standard coils are copper round tube, aluminum plate fin with optional coil coatings and copper fin design.
S
Color--coded wiring.
S
Large, laminated wiring and power wiring drawings which are affixed to unit make troubleshooting easy.
S
Single, central terminal board for test and wiring connections.
S
Fast--access, handled, panels for easy access to the blower and blower motor, control box, and compressors.
S
“No--strip” screw system guides screws into the panel and captures them tightly without stripping the screw, the panel, or
the unit.
S
Exclusive, newly--design indoor refrigerant header for easier maintenance and replacement.
S
Mechanical cooling (115_F to 25_F or 46_C to --4_C) on Electro--Mechanical (E/M) and Direct Digital Controller
(DDC) (RTU--MP controller).
S
2” (51mm) disposable filters on all units.
S
High capacity refrigerant filter--drier on each circuit.
S
High pressure switch, loss of charge switch and freeze protection adds greater unit reliability.