INSPECTION/SETUP

Refueling Procedure:

1. Level Tanks — Make sure fuel cells are level with the

ground. Failure to do so will cause fuel to spill from the
tank before reaching full capacity (Figure 31).

Figure 31. Only Fill on Level Ground

2. Remove fuel cap and fi ll tank with clean fresh #2 diesel

fuel (Figure 32).

Figure 32. Fueling the Generator

WARNING

Diesel fuel and its vapors are dangerous
to your health and the surrounding
environment. Avoid skin contact and/or
inhaling fumes.

CAUTION

ALWAYS place trailer on fi rm level ground before
refueling to prevent spilling and maximize the amount
of fuel that can be pumped into the tank.

NOTICE

ONLY use #2 diesel fuel when refueling.

3. NEVER overfi ll fuel tank — It is important to read the

fuel gauge when fi lling trailer fuel tank. DO NOT wait
for fuel to rise in fi ller neck (Figure 33).

Figure 33. Full Fuel Tank

Figure 34. Fuel Expansion

COOLANT (ANTIFREEZE/SUMMER COOLANT/
WATER)

John Deere recommends John Deere antifreeze/summer
coolant for use in their engines, which can be purchased in
concentrate (and mixed with 50% demineralized water) or
pre-diluted. See the John Deere Engine Owner’s Manual
for further details.

CAUTION

DO NOT OVERFILL fuel system. Leave room for fuel
expansion. Fuel expands when heated (Figure 34).

WARNING

If adding coolant/antifreeze mix to the
radiator, DO NOT remove the radiator cap
until the unit has completely cooled. The
possibility of hot! coolant exists which can
cause severe burns.