beautypg.com

Ab a b, Jacket water heater wiring diagram – Multiquip DCA20SPXU4F User Manual

Page 65

background image

dca20SpXU4F Servpro™ • operation manUal — rev. #0 (07/16/14) — page 65

jaCket Water heater WiriNG DiaGraM

NEMA 5-15, 15A, 120 VAC, P/N EE6176 (HBL5278C/HUBBLE RECEPTACLE).

BLACK 14 AWG.

LINE (L)120VAC INPUT

WHITE 14 AWG.

NEUTRAL (N)

GREEN 14 AWG.

GROUND (G)

NOTES:

1

2

RECEPTACLE IS MOUNTED ON OUTPUT TERMINAL PANEL ASSY.

20 AMP, 5-20R RECEPTACLE, P/N EE6131 (HBL5369C/HUBBLE RECEPTACLE).

3

GROUND

120 VAC

4

CORD, CAROL 3/C 14 AWG., P/N EE56557.

BLOCK HEATER

(P/N 44558)

120 VAC INPUT, INSERT EXTERNAL

POWER CORD HERE.

3

1

2

4

HEATING

ELEMENT

TEMP.

SWITCH

BLACK 14 AWG. LINE (L)120VAC INPUT

WHITE 14 AWG. NEUTRAL (N)

GREEN 14 AWG. GROUND (G)

1

2

3

4

A

B

A

B