Refueling Procedure:

3.

level tanks — Make sure fuel cells are level with the

ground. Failure to do so will cause fuel to spill from the

tank before reaching full capacity (Figure 19).

Figure 19. Only Fill on Level Ground

4. Open cabinet doors on the “right side” of the generator

(from generator control panel position). Remove fuel

cap and fill tank (Figure 20).

Figure 20. Fueling the Generator

Warning

Diesel fuel and its vapors are dangerous

to your health and the surrounding

environment. Avoid skin contact and/or

inhaling fumes.

caUtion

alWaYS place trailer on firm level ground before

refueling to prevent spilling and maximize the amount

of fuel that can be pumped into the tank.

Level Ground

Unlevel Ground

=

Level Ground

Unlevel Ground

DO NOT

fill on

unlevel ground

!

!

300

20

NOTICE

onlY use #2 diesel fuel when refueling.

5.

never overfill fuel tank — It is important to read the

fuel gauge when filling trailer fuel tank.

do not wait

for fuel to rise in filler neck (Figure 21).

Figure 21. Full Fuel Tank

Figure 22. Fuel Expansion

coolant (antiFreeze/SUmmer coolant/

Water)

isuzu recommends antifreeze/summer coolant for use in their

engines, which can be purchased in concentrate (and mixed

with 50% demineralized water) or pre-diluted. See the

John

isuzu engine owner’s manual for further details.

caUtion

do not overFill fuel system. Leave room for fuel

expansion. Fuel expands when heated (Figure 22).

Warning

If adding coolant/antifreeze mix to the

radiator,

do not remove the radiator cap

until the unit has completely cooled. The

possibility of

hot! coolant exists which can

cause severe burns.