Refueling Procedure:
3.
level tanks — Make sure fuel cells are level with the
ground. Failure to do so will cause fuel to spill from the
tank before reaching full capacity (Figure 19).
Figure 19. Only Fill on Level Ground
4. Open cabinet doors on the “right side” of the generator
(from generator control panel position). Remove fuel
cap and fill tank (Figure 20).
Figure 20. Fueling the Generator
Warning
Diesel fuel and its vapors are dangerous
to your health and the surrounding
environment. Avoid skin contact and/or
inhaling fumes.
caUtion
alWaYS place trailer on firm level ground before
refueling to prevent spilling and maximize the amount
of fuel that can be pumped into the tank.
Level Ground
Unlevel Ground
=
Level Ground
Unlevel Ground
DO NOT
fill on
unlevel ground
!
!
300
20
NOTICE
onlY use #2 diesel fuel when refueling.
5.
never overfill fuel tank — It is important to read the
fuel gauge when filling trailer fuel tank.
do not wait
for fuel to rise in filler neck (Figure 21).
Figure 21. Full Fuel Tank
Figure 22. Fuel Expansion
coolant (antiFreeze/SUmmer coolant/
Water)
isuzu recommends antifreeze/summer coolant for use in their
engines, which can be purchased in concentrate (and mixed
with 50% demineralized water) or pre-diluted. See the
John
isuzu engine owner’s manual for further details.
caUtion
do not overFill fuel system. Leave room for fuel
expansion. Fuel expands when heated (Figure 22).
Warning
If adding coolant/antifreeze mix to the
radiator,
do not remove the radiator cap
until the unit has completely cooled. The
possibility of
hot! coolant exists which can
cause severe burns.