beautypg.com

Maintenance – Multiquip DCA20SPXU4F User Manual

Page 40

background image

page 40 — dca20SpXU4F Servpro™ • operation and partS manUal — rev. #0 (07/16/14)

MaiNteNaNCe

radiator cleaning

The radiator (Figure 47) should be sprayed (cleaned) with

a high pressure washer when excessive amounts of dirt

and debris have accumulated on the cooling fins or tube.

When using a high pressure washer, stand at least 5 feet

(1.5 meters) away from the radiator to prevent damage to

the fins and tube.

Figure 47. Radiator Cleaning

generator Storage

For long term storage of the generator the following is

recommended:

„

Drain the fuel tank completely. Treat with a fuel stabilizer

if necessary.

„

Completely drain the oil from the crankcase and refill if

necessary with fresh oil.

„

Clean the entire generator, internal and external.

„

Cover the generating set and store in a clean, dry place.

„

Disconnect the battery.

„

Make sure engine coolant is at proper level.

„

If generator is mounted on a trailer, jack trailer up and

place on blocks so tires do not touch the ground or block

and completely remove the tires.

Jacket Water Heater and internal BatterY

cHarger 120 vac inpUt receptacleS

(optional)

This generator can be optionally equipped with two 120

VAC, 20 amp input receptacles located on the output

terminal panel.

The purpose of these receptacles is to provide power via

commercial power to the

jacket water heater and internal

battery charger.
These receptacles will

onlY function when commercial

power has been supplied to them (Figure 48). To apply

commercial power to these receptacles, a power cord of

adequate size will be required (See Table 6).
When using the generator in

hot climates there is no

reason to apply power to jacket water heater. However, if the

generator will be used in

cold climates it is always a good

idea to apply power to the jacket water heater at all times.
To apply power to the jacket water heater simply apply

power to the jacket water heater receptacle via commercial

power using a power cord of adequate size.

Figure 48. Battery Charger and Jacket Water

Heater Power Connections

If the generator will be used daily, the battery should

normally not require charging. If the generator will be idle

(not used) for long periods of time, apply power to the

battery charger receptacle via commercial power using a

power cord of adequate size.

BATTERY CHARGER

BATTERY CHARGER/

JACKET WATER HEATER

120 VAC INPUT

RECEPTACLE

OUTPUT TERMINAL

PANEL ASSEMBLY

JACKET WATER

HEATER

NOTICE

To ensure adequate starting capability, always have

power applied to the generator's internal battery

charger.