Lenze EVF9383 User Manual
Ä.7neä, 9300 vector
Table of contents
Document Outline
- Preface
- Configuration
- Configuration by means of Global Drive Control
- Basic configuration
- Changing the basic configuration
- Control
- Speed control (C0005 = 1000)
- Step control (C0005 = 2000)
- Traversing control (C0005 = 3000)
- Torque control (C0005 = 4000)
- Digital frequency - master (C0005 = 5000)
- Digital frequency - slave (bus) (C0005 = 6000)
- Digital frequency - slave (cascade) (C0005 = 7000)
- Dancer position control with external diameter detection (C0005 = 8000)
- Dancer position control with internal diameter detection (C0005 = 9000)
- Use of function blocks
- Function blocks
- List of function blocks
- List of free control codes
- Absolute value generation (ABS)
- Addition (ADD)
- Automation interface (AIF-IN)
- Automation interface (AIF-OUT)
- Analog inputs via terminal X6/1,2 and X6 / 3,4 (AIN)
- Logic AND (AND)
- Inversion (ANEG)
- Analog outputs via terminals X6/62 and X6/63 (AOUT)
- Arithmetic (ARIT)
- Toggling (ASW)
- Holding brake (BRK)
- System bus (CAN-IN)
- System bus (CAN-OUT)
- Comparison (CMP)
- Conversion (CONV)
- Conversion phase to analog (CONVPHA)
- Characteristic function (CURVE)
- Dead band (DB)
- Diameter calculator (DCALC)
- Device control (DCTRL)
- Digital frequency input (DFIN)
- Digital frequency output (DFOUT)
- Digital frequency ramp function generator (DFRFG)
- Digital frequency processing (DFSET)
- Delay (DIGDEL)
- Digital inputs (DIGIN)
- Digital outputs (DIGOUT)
- Differentiation (DT1-1)
- Counter (FCNT)
- Free digital outputs (FDO)
- Code assignment (FEVAN)
- Programming of fixed setpoints (FIXSET)
- Flipflop (FLIP)
- Curve follower (FOLL)
- Integrator (INT)
- Limitation (LIM)
- Internal motor control with V/f characteristic control (MCTRL1)
- Internal motor control with vector control (MCTRL2)
- Mains failure control (MFAIL)
- Motor phase failure detection (MLP)
- Monitor outputs of monitoring system (MONIT)
- Motor potentiometer (MPOT)
- Blocking frequencies (NLIM)
- Logic NOT
- Speed preconditioning (NSET)
- Logic OR
- Oscilloscope function (OSZ)
- Process controller (PCTRL)
- Delay (PT1)
- Ramp function generator (RFG)
- CW/CCW/Quick stop (R/L/Q)
- Sample & Hold (S&H)
- Square-root calculator (SQRT)
- S-ramp function generator (SRFG)
- Output of digital status signals (STAT)
- Edge evaluation (TRANS)
- Application examples
- Signal-flow charts
- How to read the signal-flow charts
- Speed control (C0005 = 1000)
- Step control (C0005 = 2000)
- Traversing control (C0005 = 3000)
- Torque control (C0005 = 4000)
- Digital frequency master (C0005 = 5000)
- Digital frequency bus (C0005 = 6000)
- Digital frequency cascade (C0005 = 7000)
- Dancer position control (external diameter calculator) (C0005 = 8000)
- Dancer position control (internal diameter calculator) (C0005 = 9000)
- Appendix