Motor potentiometer (mpot), Configuration, 44 motor potentiometer (mpot) – Lenze EVF9383 User Manual
Page 137: Range of functions, Control of the motor potentiometer, Deactivation of the motor potentiometer

Configuration
2−129
l
EDSVF9383V−EXT EN 2.0
2.4.44
Motor potentiometer (MPOT)
This FB is used as an alternative setpoint source which is triggered by two inputs.
C0260
C0262
MPOT1
MPOT1−OUT
MPOT
CRTL
C0269/1
C0269/2
C0269/3
MPOT1−DOWN
MPOT1−INACT
MPOT1−UP
C0264
C0263
C0261
C0267/1
C0268
C0267/2
C0265
Fig. 2−101
Motor potentiometer (MPOT1)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
MPOT1−UP
d
C0269/1
bin
C0267/1
2
1000
−
MPOT1−INACT
d
C0269/3
bin
C0268
2
1000
−
MPOT1−DOWN
d
C0269/2
bin
C0267/2
2
1000
−
MPOT1−OUT
a
−
−
−
−
−
Range of functions
l
Control of the motor potentiometer
l
Deactivation of the motor potentiometer
l
Initialization of the motor potentiometer
2.4.44.1
Control of the motor potentiometer
l
MPOT1−UP = HIGH
– The motor potentiometer approaches its upper limit.
l
MPOT1−DOWN = HIGH
– The motor potentiometer approaches its lower limit.
l
MPOT1−UP = LOW and MPOT1−DOWN = LOW or
MPOT1−UP = HIGH and MPOT1−DOWN = HIGH:
– The motor potentiometer does not change its output signal.
Tir
Tir
Tir
Tif
MPOT1−UP
MPOT1−DOWN
C0260
C0261
0
+
−
MPOT1−OUT
Fig. 2−102
Control signals of the motor potentiometer