Configuration – Lenze EVF9383 User Manual
Page 106

Configuration
2−98
l
EDSVF9383V−EXT EN 2.0
Comparing counter
l
C1100 = 1
– If | counter content |
³ | FCNT1−CMP−VAL | (comparison value), FCNT1−EQUAL is set = HIGH
for 1 ms. Afterwards the counter is reset to the starting value (FCNT1−LD−VAL).
)
Note!
If the signal is to be available longer, e. g. for a query of the output via a PLC, you
can prolong the signal via the TRANS function block.
l
C1100 = 2
– If | counter content |
³ | FCNT1−CMP−VAL | (comparison value), the counter is stopped.
– Via FCNT1−LOAD = HIGH, the counter is reset to the starting value (FCNT1−LD−VAL).
l
C1100 = 3
– If | counter content| = | FCNT1−CMP−VAL | (comparison value), the counter is stopped.
– Via FCNT1−LOAD = HIGH, the counter is reset to the starting value (FCNT1−LD−VAL).