Troubleshooting and fault elimination
8-4
UONu_^MPMQ
L
Display
Remedy
Cause
Fault
OH51
PTC monitoring (Warning)
IMotor too hot because of
excessive current or frequent
and too long acceleration
Check drive selection
IPTC not connected
Connect PTC or switch off monitoring
OV
Overvoltage
Mains voltage too high
Check voltage supply
OV
Overvoltage
Feedback operation
Braking operation
D
Increase deceleration times.
D
For operation with brake choppers:
- Check the selection and
connection of the brake resistor
- Increase the deceleration times
Earth leakage on the motor side
Check motor cable and motor for earth
fault (disconnect motor from inverter)
rSt
Faulty auto-TRIP reset
More than 8 fault messages in
10 minutes
Depends on the fault message
Pr
Faulty parameter transfer
via the operating module
PAR1 and PAR2 are defective.
It is absolutely necessary to repeat the
data transfer or load the factory setting
b f
bli
h
ll
Pr1
Faulty PAR1 transfer via
the operating module
PAR1 is defective.
data transfer or load the factory setting
before enabling the controller.
Pr2
Faulty PAR2 transfer via
the operating module
PAR2 is defective.
Show/Hide Bookmarks