Configuration – Lenze 8210 series User Manual
Page 57

Configuration
UONu_^MPMQ
7-7
L
Code
IMPORTANT
Possible settings
Name
Code
IMPORTANT
Info
Selection
Lenze
Name
C099
*
Software version
Only display
*
820X
82 1x (Software 1x)
821X
82 2x (Software 2x)
82 1x (Software 1x)
822X/824X
82 1x (Software 1x)
C105 Deceleration time
quick stop
821X/822X/824X
5.00
0.00
{0.01s}
999.00
C106 Holding time for
autom. DC
injection brake
820X 0.00
0.00
{0.01s}
50.00
821X/822X
824X
0.02
0.00
{0.01s}
999.00
C108
*
Gain (C111)
*
820X
220
0
{1}
255
821X
128
0
{1}
255
822X/824X
128
0
{1}
255
C111
¿
Monitor signal
-0-
-0- Field frequency
-1- Controller load
-2- Motor current
-3- DC-bus voltage
C117
¿
Function relay K2
822X/824X
-0-
-0- Ready for operation
-1- TRIP fault message
-2- Motor is running
-3- Motor is running / CW rotation
-4- Motor is running / CCW rotation
-5- Field frequency f
d
= 0
-6- f
dSet
reached
-7- Q
min
reached
-8- I
max
reached
-9- Overtemperature (
J
max
-10
°C)
-10- TRIP or Q
min
or IMP
-11- PTC warning
C119
¿
Function PTC
822X/824X
-0-
-0- PTC input inactive
-1- PTC input active,
TRIP and IMP (pulse inhibit) are set
-2- PTC input active, warning
C120 I
2
¡ t switch off
822X/824X
0
0
{1 %}
100
Show/Hide Bookmarks