Configuration – Lenze 8210 series User Manual
Page 58

Configuration
7-8
UONu_^MPMQ
L
Code
IMPORTANT
Possible settings
Name
Code
IMPORTANT
Info
Selection
Lenze
Name
C125
¿*
LECOM baud rate
-0-
-0- 9600 baud
-1- 4800 baud
-2- 2400 baud
-3- 1200 baud
-4- 19200 baud
Only for LECOM
applications
C142
¿
Start condition
-1-
-0- Automatic start inhibited,
flying-restart circuit inactive
-1- Automatic start, if term. 28 HIGH,
flying-restart circuit not active
-2- Automatic start inhibited,
flying-restart circuit active
-3- Automatic start, if term. 28 HIGH,
flying-restart circuit active
C144
¿
Chopper-
frequency
reduction
821X/822X/824X
-1-
-0- No chopper-frequency reduction
-1- Automatic chopper-frequency
lowering when
J
max
- 10
°C
C161
*
Current fault
Only display
C162
*
Last fault
Only display
C163
*
Last but one fault
Only display
C164
*
Last but two fault
Only display
C170
¿
TRIP-reset
selection
-0- TRIP-reset by pressing the STP key or
LOW signal at ctrl. enable
-1- Auto-TRIP-Reset
C171 Delay for
Auto-TRIP-Reset
0
0
{1s}
60
C178
*
Operating time
Only display
C179
*
Mains switch-on
time
Only display
C377 Gain Zk-voltage
detection
822X/824X
Should only
be changed
by the Lenze
Service!
C500
*
Display factor
application datum
numerator
821X/822X/824X 2000 1
{1}
25000
C501
*
Display factor for
process variable
denominator
821X/822X/824X
10
1
{1}
25000