4 wiring, 1 operation with ecsxe power supply module, Wiring – Lenze ECSEKxxx User Manual
Page 55: Operation with ecsxe power supply module, Electrical installation, Stop

Electrical installation
Wiring
Operation with ECSxE power supply module
4
55
EDKCSEK002 DE/EN/FR 2.0
4.4
Wiring
Install the capacitor module between the power supply module and the axis
module(s).
If the total cable length in the DC-bus connection is longer than 5 m, install the
capacitor module as close as possible to the axis module with the highest
power.
4.4.1
Operation with ECSxE power supply module
Stop!
ƒ
Permanently bridge the charging current limitation (X26) of the
capacitor module (X26 = HIGH).
ƒ
Only release the controller (X6/SI1 = HIGH) if the power supply
module ECSxE displays ”Ready for operation” (X6/DO1 = HIGH).
t [s]
HIGH (1)
LOW (0)
ECSx
: X6/SI1
ü
ECSxE: X6/DO1
t [s]
100 %
0 %
t [s]
HIGH (1)
LOW (0)
ECSxK: X26 (24 V DC)
ECSxE: X6/DI1
ECSxE: X6/DI2
t [s]
HIGH (1)
LOW (0)
K1
U
ZK
ECSXK010
Fig. 4-1
Level/time diagrams for operation with ECSxE power supply module
ECSx
Axis module of the ECS series
ECSxE
Power supply module of the ECS series
U
DCbus
DC-bus voltage
ECSxK
Capacitor module of the ECS series
K1