Technical data
General data and operating conditions
2
42
EDKCSEK002 DE/EN/FR 2.0
2
Technical data
2.1
General data and operating conditions
Standards and operating conditions
Conformity
CE
Low-Voltage Directive (2006/95/EC)
Approvals
UL 508C
Power Conversion Equipment
Underwriter Laboratories (File No. E132659)
for USA and Canada
Packaging (DIN 4180)
Shipping package
Installation
Installation in control cabinet
Mounting position
Vertically suspended
Free space
above
≥
65 mm
below
≥
65 mm
With ECSZS000X0B shield mounting kit: > 195 mm
to the sides
Can be mounted directly side by side without any clearance
Environmental conditions
Climate
3k3 in accordance with IEC/EN
60721-3-3
Condensation, splash water and ice
formation not permissible.
Storage
IEC/EN 60721-3-1
1K3 (-25 ... + 55 °C)
Transport
IEC/EN 60721-3-2
2K3 (-25 ... +70 °C)
Operation
IEC/EN 60721-3-3
3K3 (0 ... + 55 °C)
Atmospheric pressure: 86 ... 106 kPa
Above +40 °C: reduce the rated
output current by 2 %/°C.
Site altitude
0 ... 4000 m amsl
Reduce rated output current by
5 %/1000 m above 1000 m amsl.
Over 2000 m amsl: use is only
permitted in environments with
overvoltage category II
Pollution
VDE 0110 part 2 pollution degree 2
Vibration resistance
Accelerational stability up to 0.7 g (Germanischer Lloyd, general conditions)