6 right/left/quickstop (l_rlq), Right/left/quickstop (l_rlq), Function library lenzedrive.lib – Lenze DDS Function library Drive User Manual
Page 93: Special functions

Function library LenzeDrive.lib
Special functions
2.7.6
Right/Left/Quickstop (L_RLQ)
2−83
L
LenzeDrive.lib EN 1.7
2.7.6
Right/Left/Quickstop (L_RLQ)
This FB links the input for the direction of rotation and the QSP function, and is safe against an open
circuit.
bCw_b
L_RLQ
bQSP_b
bCwCCw_b
bCCw_b
Fig. 2−79
Right/Left/Quickstop (L_RLQ)
VariableName
DataType
SignalType
VariableType
Note
bCw_b
Bool
binary
VAR_INPUT
Right
bCCw_b
Bool
binary
VAR_INPUT
Left
bCwCCw_b
Bool
binary
VAR_OUTPUT
Status Right/Left
bQSP_b
Bool
binary
VAR_OUTPUT
Set Quickstop
Function
·
After mains connection and simultaneous TRUE at both inputs, the outputs are set as
follows:
Inputs
Outputs
bCw_b
bCCw_b
bCwCCw_b
bQSP_b
1
1
0
1
0 = FALSE
1 = TRUE
·
The following truth−table results only if the inputs were set to TRUE once after power
switch−on
Inputs
Outputs
bCw_b
bCCw_b
bCwCCw_b
bQSP_b
0
0
0
1
1
0
1
0
0
1
1
0
1
1
unchanged
unchanged
0 = FALSE
1 = TRUE
If you set both inputs to TRUE during operation, both outputs still have their previous output value.