9 manufacturer-specific information parameters, 1 overview, 2 description of the objects – Lenze 931M-931W User Manual
Page 90: Overview, Description of the objects, Parameter setting

Parameter setting
Manufacturer-specific information parameters
Overview
7
90
KHB 13.0003-EN 2.0
7.9
Manufacturer-specific information parameters
7.9.1
Overview
In this chapter, additional objects have been created which go beyond the objects in
DSP301 and DSP402. These objects are described in the following.
7.9.2
Description of the objects
Index
Name
Possible settings
Characteristics
Lenze
Selection
Description
200F
h
0 remote_request
0
{1}
1
VAR
UINT8
RW
MAP
Requesting the control
authority.
Cannot be saved (when the
controller is restarted, the
control authority has to be
requested again).
Value
Meaning
1
Requesting the control
authority via the CAN bus
Bit 15 of the control word
need not be set to ”1”.
The control authority can
still only be requested via bit
15 of the control word.
0
Not requesting the control
authority via the CAN bus
2001
h
0 actual_drive_
temperature
{1 °C}
VAR
INT16
RO
—
Reading the current motor
temperature.
2002
h
0 actual_device_
temperature
{1 °C}
VAR
INT8
RO
—
Reading the current
controller temperature.
2003
h
0 actual_brake_
voltage
{1 mV}
VAR
UINT16 RO
MAP
Reading the current brake
voltage.
2007
h
0 absolute_
resolver_position
-1
{1 inc}
VAR
INT16
RW
—
Determining the absolute
resolver position within one
revolution.
2008
h
Maximum_control _
difference
0 number_of_
supported_entries
00
h
{1
h
}
02
h VAR
UINT8
RO
—
Maximally supported
subindices.
02
h
Three subindices are
supported.
1 maximum_
positive_
control_difference
{1 rpm}
VAR
UINT16 RW
—
Set the setting to 0 to start
measurement.
2 maximum_
negative_
control_difference
{1 rpm}
VAR
UINT16 RW
—
Set the setting to 0 to start
measurement.