C1216
C1217
C1219
Parameter | Name:
C1216 | User-specific device name
Data type: VISIBLE_STRING
Index: 23359 = 0x5B3F
The device name can be defined with maximally 25 characters by the user.
The following characters can be used for creating or changing the name:
• Letters: A ... Z, a ... z
• Numbers: 0 ... 9
• Special characters: "." and "-"
Characters deviating from this are replaced by a point.
The device name can also be entered on the gateway configuration web page.
Notes:
• The device name is saved in the communication module with mains failure protection.
• The automatic transfer of the device name to a DNS server does not take place.
• By loading the Lenze standard setting (via code
), the device name is neither reset nor changed.
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C1217 | Cycle time for CAN device monitoring
Data type: UNSIGNED_32
Index: 23358 = 0x5B3E
This code serves to set the cycle time for CAN device monitoring (
).
The cycle time can also be set via the gateway configuration web page.
Setting range
(min. value | unit | max. value)
Lenze setting
1000
MS
30000 5000 ms
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C1219 | Activation of CAN device monitoring
Data type: UNSIGNED_32
Index: 23356 = 0x5B3C
The activated device monitoring enables the detection of bus nodes with disturbed bus communication.
The device monitoring function can also be activated via code
or the gateway configuration web page.
Selection list
(Lenze setting printed in bold)
0 Not activated
1 activated
Read access Write access CINH PLC STOP No transfer