4 technical data, 1 general data and operating conditions, Technical data – Lenze EMF2180IB User Manual
Page 14: General data and operating conditions, 4technical data
4
Technical data
4.1
General data and operating conditions
14
Lenze · EMF2180IB communication module (EthernetCAN) · Communication Manual · DMS 5.0 EN · 07/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4
Technical data
4.1
General data and operating conditions
Range
Values
Order designation
EMF2180IB
Communication media (system)
CAN (ISO 11898)
Ethernet (100 Base TX, IEEE802.3u)
Number of nodes at the CAN bus
Max. 100
Baud rate
• For communication via CAN
• 20 kbit/s
• 50 kbit/s
• 125 kbit/s
• 250 kbit/s
• 500 kbit/s
• 1000 kbps
• For communication via Ethernet
• 10 Mbps
• 100 Mbits/s
Voltage supply (external) via
separate power supply unit
18 ... 30 V DC, max. 100 mA (in compliance with IEC/EN 61131-2)
Conformity and approval
CE See hardware manual of the used Inverter.
UL See hardware manual of the used Inverter.
EAC TP TC 020/2011
(TR ZU 020/2011)
Electromagnetic compatibility of
technical means
Eurasian Conformity
TR CU: Technical Regulation of Cus-
toms Union
TP TC 004/2011
(TR ZU 004/2011)
On safety of low voltage equipment
Operating conditions
Values
Deviations from standard
Climatic conditions
Storage 1 K3 to IEC/EN 60721-3-1
- 10 °C ... + 60 °C
Transport 2 K3 to IEC/EN 60721-3-2
- 10 °C ... + 70 °C
Operation 3 K3 to IEC/EN 60721-3-3
- 0 °C ... + 60 °C
Enclosure of the plugged
communication module
IP20
Degree of pollution
2 to IEC/EN 61800-5-1