3 load parameter set ( pnu 970), 4 transfer to the non-volatile memory ( pnu 971), Load parameter set (pnu 970) – Lenze 931W User Manual
Page 59: Transfer to the non-volatile memory (pnu 971), Parameter numbers

Parameter numbers
Device-specific parameter numbers
Load parameter set (PNU 970)
8
59
K-HB 13.0001-EN
2.1
8.2.3
Load parameter set (PNU 970)
PNU
Subindex Description
Possible settings
Data type
Lenze
Selection
970
0
Load parameter set
Unsigned 16
-256
100
Selection Meaning
0 All parameters are set to default setting
1 ... 100 Driving record 1 is set to default setting
Driving record 100 (0 of the operating program) is set to default setting
101 Reference parameters are set to default setting
102 I/O settings are set to default setting
103 Control parameters are set to default setting
104 System parameters are set to default setting
105 Service parameters are set to default setting
106 PROFIBUS parameters are set to default setting
-1 ... -100 Load driving record from non-volatile memory
Load driving record 100 (0 of the operating program) from non-volatile memory
-101 Load reference parameters from non-volatile memory
-102 Load I/O settings from non-volatile memory
-103 Load control parameters from non-volatile memory
-104 Load system parameters from non-volatile memory
-105 Load service parameters from non-volatile memory
-106 Load PROFIBUS parameters from non-volatile memory
-256 Load all parameters from non-volatile memory
Tab. 26
Load parameter set (PNU 970)
8.2.4
Transfer to the non-volatile memory (PNU 971)
PNU
Subindex Description
Possible settings
Data type
Lenze
Selection
971
0
Transfer into the non-volatile
memory
Unsigned 16
0
106
Selection Meaning
Transfer into the non-volatile memory
0 Store all parameters non-volatilely
1 ... 100 Store driving record 1 non-volatilely
Store driving record 100 (0 of operating program) non-volatilely
101 Store reference parameters non-volatilely
102 Store I/O settings non-volatilely
103 Store control parameters non-volatilely
104 Store system parameters non-volatilely
105 Store service parameters non-volatilely
106 Store PROFIBUS parameters non-volatilely
Tab. 27
Transfer to the non-volatile memory (PNU 971)