Page 76: 9troubleshooting and fault elimination

Troubleshooting and fault elimination
9
76
K-HB 13.0001-EN 2.1
9
Troubleshooting and fault elimination
Error message
Cause
Remedy
System parameter
The direction of the specified setpoints
outside the software limit switches, e.g.
positioning behind a limit switch.
Check settings of the software limit
switches.
Homing
No homing has been executed yet,
although a homing mode has been set or is
required (positioning mode).
Check homing settings/execute homing.
Homing
The following homing settings have been
made
z
Reference type: None
z
Reference start: Manually
If no homing is to be executed, no manual
start must be set.
Check homing settings. Select homing
mode or set homing start to power up.
Travel data record
When accessing the bus interface and the
operating program a logic conflict occurs.
Check entries via PROFIBUS and operating
program.