3 technical data, 1 general data and operating conditions, Technical data – Lenze 931W User Manual
Page 13: 3technical data

Technical data
General data and operating conditions
3
13
K-HB 13.0001-EN
2.1
3
Technical data
3.1
General data and operating conditions
General data
Area
Values
Communication profile
(DIN 19245 part 1 and part 3)
PROFIBUS-DP-V0
Communication medium
RS485
Drive profile
Profidrive
Network topology
Without repeater: Line / with repeaters: line or tree
PROFIBUS-DP station
Slave
Baud rate (in kbits/s)
9.6, 19.2, 93.75, 187.5, 500, 1500
Max. cable length per bus segment
1200 m (depending on the baud rate and cable type used)
External DC voltage supply
+24 V DC ±10 %
Enclosure
IP54
Operating conditions
Ambient conditions
Climatic
Storage
IEC/EN 60721-3-1
1K3 (deviation: -25 ... +70 °C)
Transport
IEC/EN 60721-3-2
2K3 (deviation: -25 ... +70 °C)
Operation
IEC/EN 60721-3-3
3K3 (deviation: 0 ... +40 °C)
Cooling
Passively via housing surface and heatsink
Pollution
EN 61800-5-1
Degree of pollution 2
Site altitude
< 1000 m amsl