Disconnecting – Koolance RM2-4U User Manual
Page 33

28
Connecting Exos Systems
Inevitably, a connection will need to be undone, either because you are adding
another cooler, or because something did not go properly during assembly. Be
sure there is no liquid within the system before unclamping a component (see
Draining for more information).
Clamps can be unlocked by inserting a small flat screw driver into the center of
the adjustment lobe and twisting. If done correctly, the clamp will snap open and
can be used again.
Disconnecting
Each time a metal clamp is removed, it will have distorted the tube beneath it.
This last portion (about 1cm, 7/16”) should be cut off to ensure a perfect fit with
the next connection.
Unlocking
Cooler nozzles are designed to grip very tightly
to the tubing. If you find it difficult to remove a
tube after unlocking a clamp, try leveraging it
off with needle-nose pliers. (As a last resort, it
can also be carefully cut length-wise along the
cooler nozzle.)