Koolance CPU-340 User Manual
Temperature sensor, Koolance cpu-330 installation guide, Installing nozzles
Temperature Sensor
Remove the protective fi lm from the CPU cooling block.
Apply metal tape to keep the temperature probe in place. DO NOT
stick metal tape or the temperature probe where the processor
comes in contact with the cooler.
You can use a zip-tie to further secure the temperature probe wire
to the CPU tubing.
CAUTION:
Be sure to attach the Koolance temperature probe to the CPU cooler
during installation. The safety features of your system may not function properly
without the correct placement of this probe, and hardware damage can result.
!
Koolance CPU-330 Installation Guide
v1.00
1
Place the temperature sensor on or
near the edge of the gold block. We
recommend placing it on the edge.
The sensor is required for proper
fan speed control and system safety
features.
DO NOT attempt to install the temperature
probe in between the processor and
cooler. Despite its thin size, it will interfere
with CPU contact or burn-out the sensor.
Installing Nozzles
Attach two G 1/4 nozzles
to the cooling block.
Nozzles sold separately.