beautypg.com

Koolance CTR-CD1224-R User Manual

Koolance Hardware

background image

ATX Shutdown Relay

Connect the female ATX lead to the motherboard’s
power switch connection (usually marked “PWR”,
“PWRSW”, “PWSW”, or “PWBT”). This is the
connection that would normally receive the chassis
power button directly.

To Motherboard

Chassis Power

Button

From

Koolance

Unit

There is no polarity orientation with the ATX
lead. For computer use, connect the male
shutdown lead from the Koolance unit to your
computer’s front chassis power button.

The ATX lead is responsible for sending the shutdown signal if any sensor
reaches the preset temperature (detailed later). This can be configured as
NC (normally closed) or NO (normally open) by attaching the two-pin wire
to the corresponding pins. For computers, use “NO” (normally open).

To Motherboard

The rear of the unit accepts various connections to integrate with your cooling system. The
temperature sensors may come pre-connected. If not, connect them per the diagram below:

Power Connection

Plug the included power harness into
the location on the rear of the unit
marked “Power”. To this, connect a 12
Volt 4-pin Molex plug from your power
supply.

Fan Connection

This unit has three connections to power radiator fans. Multiple fans can be combined into
a single plug. (A fan wiring harness is optionally available from Koolance).

CAUTION:

The total combined amperage of all fans connected to the unit can

not exceed 4.5A. The maximum load on a single fan header is 2.0A.

!

Flow Meter Connection

The cooling system can show values for one Koolance flow meter (sold separately). Connect
a flow meter to the appropriately labeled plug. (Note: INS-FM18 and INS-FM19 should
connect to the plug labeled “INS-FM17”.)

CTR-CD1224 User Manual

v 1.0

1

2

Pump Connection and Voltage Jumper

Plug the included pump wiring harness into the rear
“Pump” connector. Different plugs are provided to
connect a single 12 Volt or 24 Volt DC pump. (Max.
output power = 36W @12V, 50W @24V.) Do not
connect more than one pump.

CAUTION:

Do not power 12V pumps at the 24V setting! This

can permanently damage the pump.

!

TEMP

: Temperature sensors

shown on the front display

POWER

: Connection from

power supply, 12VDC

FAN

: Radiator fan connections

(2.0A max per plug, 4.5A total)

ATX

: Lead for

power shut-
down feature

PUMP

:

External
pump

INS-FM17/INS-FM16

:

Connect an optional flow
meter to display flow rate

ON/SYNC/OFF

:

Adjusts LED lighting
of INS-FM16 flow
meter

Pump Voltage Jumper

: Configure the pump

output for a maximum of 12-Volts or 24-Volts.
Misconfiguration could damage the pump!

Shutdown Relay

: Configure the safety

shutdown relay (labeled “ATX”) as Normally-
Open (NO) or Normally-Closed (NC).

The pump voltage jumper
should be set for the maximum
voltage capability of the pump,
either 12V or 24V.

This manual is related to the following products: