INFICON HLD6000 Refrigerant Leak Detector Interface Description User Manual
Page 28

28
LD Protocol
600
258
Param Audio alarm type
R/W UINT8
Audio alarm type
0 = Alarm off
1 = Trigger alarm
2 = Setpoint
3 = Pinpoint
(Default: Setpoint)
1161 489
Control Parameter reset
W
UINT8
Parameter reset:
0: Load factory settings
1581 62D
Meas
Acceleration
R
SINT16[3] [0] = X-value
[1] = Max (Y & Z)-value
[2] = 0
1631 65F
Meas
Light barrier voltages [V]
R
FLOAT[2]
Light barrier voltages at photodiode
Index 0: LED is off
Index 1: LED is on
1800 708
Status Active protocol IO
R
UINT8
Active interface protocol for I/O module. Defined by DIP
switch at I/O module or command 2593.
Values: See command 2593
1815 717
Status Reset source
R
UINT8
Shows the last reason of reset
2593 A21
Param Interface protocol IO
R/W UINT8
Selected interface protocol for I/O module. May be
overwrite if DIP switch at I/O module are not set to "000"
0 = LD
1= ASCII
don't use following settings for new constructions
8= 'Normal' of the HLD5000
9 = 'Simple' of the HLD500
(Default: ASCII)
2659 A63
Param Sniffer tip filter change request R/W UINT8
Sniffer tip filter change request:
0=0ff, 1=on
(Default: on)
Command
Class Name
R/W Data type Description
dez
hex
- TGF10 Tracer Gas Filler (36 pages)
- Sensistor ILS500 F Leak Detection Filler (90 pages)
- T-Guard Leak Detection Sensor (85 pages)
- T-Guard Leak Detection Sensor Interface description (40 pages)
- Sensistor ISH2000P Hydrogen Leak Detector, Panel Model (51 pages)
- Sensistor ISH2000 HySpeed Hydrogen Leak Detector (54 pages)
- LDS3000 Modular Leak Detector (52 pages)
- LDS3000 Modular Leak Detector Interface description (56 pages)
- BM1000 Bus module (14 pages)
- I/O1000 I/O module (18 pages)
- CU1000 Control unit (24 pages)
- Helium Leak Detector Modul1000 (130 pages)
- Helium Leak Detector Modul1000 Interface description (40 pages)
- UL5000 Dry Helium Leak Detector (108 pages)
- UL5000 Dry Helium Leak Detector Interface description (14 pages)
- UL1000 Fab Dry Helium Leak Detector (119 pages)
- HLD6000 Refrigerant Leak Detector (76 pages)
- IO1000 I/O module (18 pages)
- Ecotec E3000 Multigas-Sniffer-Leak Detector (92 pages)
- Ecotec E3000 Multigas-Sniffer-Leak Detector Interface description (36 pages)
- Sensistor XRS9012 Hydrogen Leak Detector User Manual (28 pages)
- Sensistor XRS9012 Hydrogen Leak Detector Maintenance manual (14 pages)
- Extrima Ex-certified Hydrogen Leak Detector (62 pages)
- Sensistor ILS500 Leak Detection System (107 pages)
- Sensistor ISH2000 Hydrogen Leak Detector (58 pages)
- Sensistor ISH2000 Hydrogen Leak Detector (108 pages)
- Sensistor Sentrac Hydrogen Leak Detector (86 pages)
- Protec P3000(XL) Helium Leak Detector (132 pages)
- Pilot Plus Vacuum Gauge (2 pages)
- CO Check Carbon Monoxide Meter (2 pages)
- GAS-Mate Combustible Gas Leak Detector (12 pages)
- Whisper Ultrasonic Leak Detector (8 pages)
- Vortex AC Refrigerant Recovery Machine 115V (20 pages)
- Vortex AC Refrigerant Recovery Machine 230V (16 pages)
- Wey-TEK Refrigerant Charging Scale & Optional Charging Module (2 pages)
- Wey-TEK Refrigerant Charging Scale & Optional Charging Module (44 pages)
- D-TEK CO2 Refrigerant Leak Detector (12 pages)
- TEK-Mate Refrigerant Leak Detector (12 pages)
- Compass Refrigerant Leak Detector (12 pages)
- D-TEK Select Refrigerant Leak Detector (12 pages)
- Explorer Portable Gas Chromatograph (369 pages)
- MicroFID II Portable Flame Ionization Detector (89 pages)
- DataFID Portable Flame Ionization Detector for Landfill Emissions Monitoring (91 pages)
- Hydrostik Hydrogen Fuel Cylinder Installation (7 pages)