Manual EKS Electronic-Key Adapter PROFINET

Seite 14/44

Subject to technical modifications

109283-01-04/10

4.4 DIP switch settings

The device has three DIP switches (S1, S2, S3).

DIP switch

Function

S1

S1.1 … S1.4; write and read settings

(4-fold)

S2.1 …

S2.8; setting for a fixed DCP name (dependent on the setting of S3)

S2

(8-fold)

S3

S3.1 …S3.4; settings for network connection and service

(4-fold)

Information!

The settings are only applied when the power supply is switched on.

4.4.1 DIP switch S1

DIP

Function

Factory setting

switch

S1.1

ON = write protection for Electronic-Key read/write

OFF

S1.2 No

function

OFF

S1.3 No

function

OFF

S1.4 No

function

OFF

Information!
It is imperative that all switches without a function (S1.2, S1.3 and S1.4) are set to OFF! In this way
problems with any functions added in the future will be avoided.