2 technical data, electronic-key adapter, Manual eks electronic-key adapter profinet – EUCHNER EKS FSA with PROFINET interface User Manual
Page 12
Manual EKS Electronic-Key Adapter PROFINET
Seite 12/44
Subject to technical modifications
109283-01-04/10
4.2 Technical data, Electronic-Key adapter
Warning!
All the electrical connections must either be isolated from the mains supply by a safety transformer
according to EN IEC 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent
isolation measures.
General parameters
Value
Unit
min.
typ.
max.
Housing
Plastic (PA 6 GF30 gray)
Degree of protection according to EN 60529
IP 67 in mounted condition
Ambient temperature at UB = 24 V DC
0
+ 55
°C
Mounting cut-out acc. to DIN 43700
33 x 68
mm
Connection for power supply
Plug-in screw terminal, 3-pole,
Conductor cross-section 0.14 ... 1.5 mm², tightening torque 0.22
Nm
Operating voltage UB
20 24 28
DC
V
(regulated, residual ripple < 5 %)
Current consumption
150
mA
Interface, data transfer
Interface to the PC
Industrial Ethernet (IEEE 802.3)
Transfer protocol
PROFINET
Data transfer rate (full duplex)
10/100
MBit/s
Data connection
1 x RJ45 socket
Data line
2 x 2 twisted-pair copper cables, screened; min. category 5
Cable length
100
m
LED display
green: "Ready" (in operation)
yellow: "Electronic-Key active" *
red: "Fault"
Parameters for the outputs LA and LB (version EKS FSA only)
Power supply for load U (LA, LB)
24
30
V
Switching current per output
1
50
mA
Number of actuations of the overload
protection
100
Output voltage high for U (LA, LB)
U x 0.9
U
V
Resistance in switched-on state
35
Ohm
Capacitance per output
2
nF
Additional capacitive load per output
1
µF
Utilization category according to AC-12
EN IEC 60947-5-2 AC-15
50 mA / 24 V
DC-12
DC-13
Difference time between the outputs** (LB
first)
200
ms
Connection screw terminals, 2 x 2-pole
0,14
1,5
mm²
* The LED lights up yellow if there is a functional electronic key in the Electronic-Key adapter.
** If access on the Ethernet interface takes place during insertion or removal of the electronic key, the difference time can
be more than 200ms.