Operating Instructions Safety System CES-AZ-UES-...

41

Pin assignment

Read head with plug connector

Technical Data

Parameter

Value

Unit

min.

typ.

max.

Housing material

Nickel-plated CuZn housing sleeve

Plastic PBT GF20 cap

Dimensions

M12 x 1, length 38

mm

Weight (incl. 10 m cable)

0.2

kg

Ambient temperature

-25

-

+70

°C

Ambient pressure
(only of active face in installed condition)

-

-

10

bar

Degree of protection

IP67

Installation position

Any

Method of operation

Inductive

Power supply

Via evaluation unit

In combination with actuator CES-A-BMB on evaluation unit CES-AZ-AES-04B

Assured switch-off distance S

ar

-

-

10

mm

Operating distance for center offset m = 0

1)

- Switch-on distance

-

5

-

- Assured switch-on distance S

ao

3.5

-

-

- Switching hysteresis

0.1

0.3

-

Connection

M8 plug connector (snap-action and screw terminals), 3-pin

Connection cable

-

-

15

m

1)

These values apply for surface installation of the read head in steel.

H11 H12 SH1

1

3

4

BN

WH

Screen

View

on plug connector

of the read head

Evaluation unit

CES-AZ-UES-...