beautypg.com

Technical data – EUCHNER MGB-LxxB-PNA-xxx (PROFINET) with Data Structure Type A User Manual

Page 32

background image

Operating Instructions Safety System MGB-L..B-PNA-... (PROFINET)

32

Technical data

Note:

If a product data sheet is included with the product, the information on the data

sheet applies in case of discrepancies with the operating instructions.

Parameter

Value

s

ar

max. door position

65 mm

Housing material

Reinforced plastic,

die-cast zinc, nickel-plated,

stainless steel,

powder-coated sheet steel

Dimensions

See dimension drawing

Weight of MGB-L.B (bus module, locking module and button module with mounting plate)

4.05 kg

Weight of handle module with mounting plate

1.20 kg

Weight of escape release module with mounting plate

1.15 kg

Ambient temperature

-20 … +55 °C

Degree of protection

IP54

Safety class

III

Degree of contamination

3

Installation position

Any

Locking force F

zh

in accordance with GS-ET-19

2,000 N

Connection options, power supply

2 x push-pull power

1)

or 2 x plug connectors 7/8" according to ANSI/B93.55M-1981

Connection type, bus

2 x RJ 45, push-pull, according to IEC 61076-3-117 type 14, screened

1)

or 2 x M12 plugs (d-coded) according to IEC 61076-2-101

Connection cable, bus

Profinet I/O cable, at least cat. 5e

Operating voltage U

B

DC 24V +10% / -15%

(PELV – see electrical connection)

Current consumption, max.

500 mA

Max. feed-in current in the connection block (push-pull plug connector)

4,000 mA

Fuse protection for power supply, external

Min. 1 A slow-blow

Safety outputs

Profisafe according to IEC 61784-3-3

Rated insulation voltage U

i

75 V

Rated impulse withstand voltage U

imp

0.5 kV

Resilience to vibration and shock

In accordance with EN 60947-5-3

EMC protection requirements

In accordance with EN 61000-4

and DIN EN 61326-3-1

Switching frequency max.

1 Hz

Risk times max. (switch-off times)

2)

- Emergency stop
- Enabling switch
- Operating mode selector switch
- Guard position
- Bolt position
- Guard locking

220 ms
220 ms
220 ms
550 ms
550 ms
550 ms

Reliability values according to EN ISO 13849-1

Category

4 (EN 13849-1:2008-12)

Performance Level

PL e (EN 13849-1:2008-12)

MTTF

d

3)

91 years

DC

99%

Mission time

20 years

PFH

d

3)

2.54 x 10

-8

/ h

B

10d

4)

- Emergency stop
- Enabling switch

1 x 10

5

According to switch information from manufacturer

1) The document PROFINET Cabling and Interconnection Technology from the PNO aids in the correct selection of wiring.
2) The risk time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.
3) Fixed failure rate without consideration of faults in wearing parts.
4) Information regarding wearing parts without consideration of fixed failure rates in electronic components.