32
Technical data
Note:
If a product data sheet is included with the product, the information on the data
sheet applies in case of discrepancies with the operating instructions.
Parameter
Value
s
ar
max. door position
65 mm
Housing material
Reinforced plastic,
die-cast zinc, nickel-plated,
stainless steel,
powder-coated sheet steel
Dimensions
See dimension drawing
Weight of MGB-L.B (bus module, locking module and button module with mounting plate)
4.05 kg
Weight of handle module with mounting plate
1.20 kg
Weight of escape release module with mounting plate
1.15 kg
Ambient temperature
-20 … +55 °C
Degree of protection
IP54
Safety class
III
Degree of contamination
3
Installation position
Any
Locking force F
zh
in accordance with GS-ET-19
2,000 N
Connection options, power supply
2 x push-pull power
1)
or 2 x plug connectors 7/8" according to ANSI/B93.55M-1981
Connection type, bus
2 x RJ 45, push-pull, according to IEC 61076-3-117 type 14, screened
1)
or 2 x M12 plugs (d-coded) according to IEC 61076-2-101
Connection cable, bus
Profinet I/O cable, at least cat. 5e
Operating voltage U
B
DC 24V +10% / -15%
(PELV – see electrical connection)
Current consumption, max.
500 mA
Max. feed-in current in the connection block (push-pull plug connector)
4,000 mA
Fuse protection for power supply, external
Min. 1 A slow-blow
Safety outputs
Profisafe according to IEC 61784-3-3
Rated insulation voltage U
i
75 V
Rated impulse withstand voltage U
imp
0.5 kV
Resilience to vibration and shock
In accordance with EN 60947-5-3
EMC protection requirements
In accordance with EN 61000-4
and DIN EN 61326-3-1
Switching frequency max.
1 Hz
Risk times max. (switch-off times)
2)
- Emergency stop
- Enabling switch
- Operating mode selector switch
- Guard position
- Bolt position
- Guard locking
220 ms
220 ms
220 ms
550 ms
550 ms
550 ms
Reliability values according to EN ISO 13849-1
Category
4 (EN 13849-1:2008-12)
Performance Level
PL e (EN 13849-1:2008-12)
MTTF
d
3)
91 years
DC
99%
Mission time
20 years
PFH
d
3)
2.54 x 10
-8
/ h
B
10d
4)
- Emergency stop
- Enabling switch
1 x 10
5
According to switch information from manufacturer
1) The document PROFINET Cabling and Interconnection Technology from the PNO aids in the correct selection of wiring.
2) The risk time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.
3) Fixed failure rate without consideration of faults in wearing parts.